High-Temp Insertion Capsule Platinum RTD (0.066" dia.) (RdF Model 29362)
These platinum RTD Capsules deliver stable, accurate temperature measurement in environments as hot as 510°C (950°F). Precision ultra-small diameter and low mass result in a super fast response time. Leads are welded and anchored to the element, adding durability. Please contact factory if desired lead length or resistance is not available online.
These platinum RTD Capsules deliver stable, accurate temperature measurement in environments as hot as 510°C (950°F). Precision ultra-small diameter and low mass result in a super fast response time. Leads are welded and anchored to the element, adding durability. Please contact factory if desired lead length or resistance is not available online.
These platinum RTD Capsules deliver stable, accurate temperature measurement in environments as hot as 510°C (950°F). Precision ultra-small diameter and low mass result in a super fast response time. Leads are welded and anchored to the element, adding durability. Please contact factory if desired lead length or resistance is not available online.
Specifications
These precision-diameter platinum RTD Capsules have insulated lead wires welded and anchored internally. No splicing to fragile elements is required. This construction assures reliable rugged embedment, insertion or probe assembly. Fit in precision diameter.
Also available in widths ranging from 0.086” to 0.187”, custom lead lengths and moisture-resistant. Visit rdfcorp.com or contact sales@rdfcorp.com for more information.
Sensing Element | Temperature Range | Ice Point Resistance | Time Constant |
---|---|---|---|
International grade thin film platinum a = 0.00385 Ω/Ω/°C per IEC 751 |
Fiberglass leads: -75 to 510°C (-100 to 950°F) |
100±0.12Ω or 1000Ω±1.2Ω International Class B: (±0.12%) |
(Water at 3ft/sec) = 0.4 seconds |
Self Heating | Interchangeability | Long Term Stability | Insulation Resistance |
> 15 mW/°C mounted (8.3 mW/°F) |
±(0.3°C @ 0°C + 0.005 |t|°C) IEC 751 Class B above –50°C | Better than 0.05°C (0.02% of resistance) per 5 years from -60°C to 300°C, 0.25°C per year to 510°C | > 50 MegOhms at 50VDC at 25°C (77°F) |
Maximum Current | Recommended Current | Case Material | Lead Materials |
100Ω = 5 mA, 1000Ω = 2 mA for limited seIf heating. Also suitable as self-heated sensors. |
1 mA maximum for temperature sensing | Stainless Steel 0.066" diameter x 0.6” long (1.6764 mm diameter x 15.24 mm long) |
30 AWG solid copper, nickel plated, two-wire cable with fiberglass over each lead, natural and black, fiberglass overall, 510°C (950°F) |